BSENS GROUP

Our Commencing Projects

TECHNICAL WORK PACKAGE CIVIL AND ERECTION (GBT) WORK
SNTOWER FAMILYTYPESUBTYPE1SUBTYPE2SUBTYPE3COMBINATION
1OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS NOWT 5SBC RAFT KITTED
2OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS NOWT 7.5SBC RAFT KITTED
3OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS NOWT 10SBC RAFT KITTED
4OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS NOWT 15SBC RAFT KITTED
5OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS WT 5SBC RAFT KITTED
6OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS WT 7.5SBC RAFT KITTED
7OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS WT 10SBC RAFT KITTED
8OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 39WS WT 15SBC RAFT KITTED
9OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS NOWT 5SBC RAFT KITTED
10OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS NOWT 7.5SBC RAFT KITTED
11OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS NOWT 10SBC RAFT KITTED
12OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS NOWT 15SBC RAFT KITTED
13OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS WT 5SBC RAFT KITTED
14OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS WT 7.5SBC RAFT KITTED
15OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS WT 10SBC RAFT KITTED
16OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 47WS WT 15SBC RAFT KITTED
17OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS NOWT 5SBC RAFT KITTED
18OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS NOWT 7.5SBC RAFT KITTED
19OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS NOWT 10SBC RAFT KITTED
20OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS NOWT 15SBC RAFT KITTED
21OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS WT 5SBC RAFT KITTED
22OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS WT 7.5SBC RAFT KITTED
23OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS WT 10SBC RAFT KITTED
24OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 50WS WT 15SBC RAFT KITTED
25OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLEKITTEDRAMBALL – 40MTR GBT 55WS NOWT 5SBC RAFT KITTED
26OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS NOWT 5SBC RAFT NON KITTED
27OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS NOWT 7.5SBC RAFT NON KITTED
28OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS NOWT 10SBC RAFT NON KITTED
29OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS NOWT 15SBC RAFT NON KITTED
30OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS WT 5SBC RAFT NON KITTED
31OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS WT 7.5SBC RAFT NON KITTED
32OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS WT 10SBC RAFT NON KITTED
33OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 39WS WT 15SBC RAFT NON KITTED
34OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS NOWT 5SBC RAFT NON KITTED
35OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS NOWT 7.5SBC RAFT NON KITTED
36OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS NOWT 10SBC RAFT NON KITTED
37OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS NOWT 15SBC RAFT NON KITTED
38OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS WT 5SBC RAFT NON KITTED
39OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS WT 7.5SBC RAFT NON KITTED
40OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS WT 10SBC RAFT NON KITTED
41OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 47WS WT 15SBC RAFT NON KITTED
42OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS NOWT 5SBC RAFT NON KITTED
43OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS NOWT 7.5SBC RAFT NON KITTED
44OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS NOWT 10SBC RAFT NON KITTED
45OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS NOWT 15SBC RAFT NON KITTED
46OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS WT 5SBC RAFT NON KITTED
47OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS WT 7.5SBC RAFT NON KITTED
48OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS WT 10SBC RAFT NON KITTED
49OWN BUILTGBTRAMBALL – 40MTRWITH WATER TABLENON KITTEDRAMBALL – 40MTR GBT 50WS WT 15SBC RAFT NON KITTED
50OWN BUILTGBTRAMBALL – 40MTRW/O WATER TABLENON KITTEDRAMBALL – 40MTR GBT 55WS NOWT 5SBC RAFT NON KITTED
51OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 39WS NOWT 5SBC RAFT KITTED
52OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 39WS NOWT 7.5SBC RAFT KITTED
53OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 39WS NOWT 10-15SBC RAFT KITTED
54OWN BUILTGBTRAMBALL – 30MTRWITH WATER TABLEKITTEDRAMBALL – 30MTR GBT 39WS WT 5-15SBC RAFT KITTED
55OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 47WS NOWT 5SBC RAFT KITTED
56OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 47WS NOWT 7.5SBC RAFT KITTED
57OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 47WS NOWT 10SBC RAFT KITTED
58OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 50WS NOWT 5SBC RAFT KITTED
59OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLEKITTEDRAMBALL – 30MTR GBT 50WS NOWT 7.5-15SBC RAFT KITTED
60OWN BUILTGBTRAMBALL – 30MTRWITH WATER TABLEKITTEDRAMBALL – 30MTR GBT 50WS WT 5-15SBC RAFT KITTED
61OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 39WS NOWT 5SBC RAFT NON KITTED
62OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 39WS NOWT 7.5SBC RAFT NON KITTED
63OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 39WS NOWT 10-15SBC RAFT NON KITTED
64OWN BUILTGBTRAMBALL – 30MTRWITH WATER TABLENON KITTEDRAMBALL – 30MTR GBT 39WS WT 5-15SBC RAFT NON KITTED
65OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 47WS NOWT 5SBC RAFT NON KITTED
66OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 47WS NOWT 7.5SBC RAFT NON KITTED
67OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 47WS NOWT 10SBC RAFT NON KITTED
68OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 50WS NOWT 5SBC RAFT NON KITTED
69OWN BUILTGBTRAMBALL – 30MTRW/O WATER TABLENON KITTEDRAMBALL – 30MTR GBT 50WS NOWT 7.5-15SBC RAFT NON KITTED
70OWN BUILTGBTRAMBALL – 30MTRWITH WATER TABLENON KITTEDRAMBALL – 30MTR GBT 50WS WT 5-15SBC RAFT NON KITTED
71OWN BUILTRTT12MTR39WSKITTEDRTT 12MTR 39WS G+2 KITTED
72OWN BUILTRTT12MTR39WSKITTEDRTT 12MTR 39WS G+3 KITTED
73OWN BUILTRTT12MTR39WSKITTEDRTT 12MTR 39WS G+4 KITTED
74OWN BUILTRTT12MTR47WSKITTEDRTT 12MTR 47WS G+2 KITTED
75OWN BUILTRTT12MTR47WSKITTEDRTT 12MTR 47WS G+3 KITTED
76OWN BUILTRTT12MTR47WSKITTEDRTT 12MTR 47WS G+4 KITTED
77OWN BUILTRTT12MTR50WSKITTEDRTT 12MTR 50WS G+2 KITTED
78OWN BUILTRTT12MTR50WSKITTEDRTT 12MTR 50WS G+3 KITTED
79OWN BUILTRTT12MTR50WSKITTEDRTT 12MTR 50WS G+4 KITTED
80OWN BUILTRTT15MTR39WSKITTEDRTT 15MTR 39WS G+2 KITTED
81OWN BUILTRTT15MTR39WSKITTEDRTT 15MTR 39WS G+3 KITTED
82OWN BUILTRTT15MTR39WSKITTEDRTT 15MTR 39WS G+4 KITTED
83OWN BUILTRTT15MTR47WSKITTEDRTT 15MTR 47WS G+2 KITTED
84OWN BUILTRTT15MTR47WSKITTEDRTT 15MTR 47WS G+3 KITTED
85OWN BUILTRTT15MTR47WSKITTEDRTT 15MTR 47WS G+4 KITTED
86OWN BUILTRTT15MTR50WSKITTEDRTT 15MTR 50WS G+2 KITTED
87OWN BUILTRTT15MTR50WSKITTEDRTT 15MTR 50WS G+3 KITTED
88OWN BUILTRTT15MTR50WSKITTEDRTT 15MTR 50WS G+4 KITTED
89OWN BUILTRTT12MTR39WSNON KITTEDRTT 12MTR 39WS G+2 NON KITTED
90OWN BUILTRTT12MTR39WSNON KITTEDRTT 12MTR 39WS G+3 NON KITTED
91OWN BUILTRTT12MTR39WSNON KITTEDRTT 12MTR 39WS G+4 NON KITTED
92OWN BUILTRTT12MTR47WSNON KITTEDRTT 12MTR 47WS G+2 NON KITTED
93OWN BUILTRTT12MTR47WSNON KITTEDRTT 12MTR 47WS G+3 NON KITTED
94OWN BUILTRTT12MTR47WSNON KITTEDRTT 12MTR 47WS G+4 NON KITTED
95OWN BUILTRTT12MTR50WSNON KITTEDRTT 12MTR 50WS G+2 NON KITTED
96OWN BUILTRTT12MTR50WSNON KITTEDRTT 12MTR 50WS G+3 NON KITTED
97OWN BUILTRTT12MTR50WSNON KITTEDRTT 12MTR 50WS G+4 NON KITTED
98OWN BUILTRTT15MTR39WSNON KITTEDRTT 15MTR 39WS G+2 NON KITTED
99OWN BUILTRTT15MTR39WSNON KITTEDRTT 15MTR 39WS G+3 NON KITTED
100OWN BUILTRTT15MTR39WSNON KITTEDRTT 15MTR 39WS G+4 NON KITTED
101OWN BUILTRTT15MTR47WSNON KITTEDRTT 15MTR 47WS G+2 NON KITTED
102OWN BUILTRTT15MTR47WSNON KITTEDRTT 15MTR 47WS G+3 NON KITTED
103OWN BUILTRTT15MTR47WSNON KITTEDRTT 15MTR 47WS G+4 NON KITTED
104OWN BUILTRTT15MTR50WSNON KITTEDRTT 15MTR 50WS G+2 NON KITTED
105OWN BUILTRTT15MTR50WSNON KITTEDRTT 15MTR 50WS G+3 NON KITTED
106OWN BUILTRTT15MTR50WSNON KITTEDRTT 15MTR 50WS G+4 NON KITTED
107OWN BUILTRTT6MTR39WSKITTEDRTT 6MTR 39WS G+2 KITTED
108OWN BUILTRTT6MTR39WSKITTEDRTT 6MTR 39WS G+3 KITTED
109OWN BUILTRTT6MTR39WSKITTEDRTT 6MTR 39WS G+4 KITTED
110OWN BUILTRTT6MTR47WSKITTEDRTT 6MTR 47WS G+2 KITTED
111OWN BUILTRTT6MTR47WSKITTEDRTT 6MTR 47WS G+3 KITTED
112OWN BUILTRTT6MTR47WSKITTEDRTT 6MTR 47WS G+4 KITTED
113OWN BUILTRTT6MTR50WSKITTEDRTT 6MTR 50WS G+2 KITTED
114OWN BUILTRTT6MTR50WSKITTEDRTT 6MTR 50WS G+3 KITTED
115OWN BUILTRTT6MTR50WSKITTEDRTT 6MTR 50WS G+4 KITTED
116OWN BUILTRTT9MTR39WSKITTEDRTT 9MTR 39WS G+2 KITTED
117OWN BUILTRTT9MTR39WSKITTEDRTT 9MTR 39WS G+3 KITTED
118OWN BUILTRTT9MTR39WSKITTEDRTT 9MTR 39WS G+4 KITTED
119OWN BUILTRTT9MTR47WSKITTEDRTT 9MTR 47WS G+2 KITTED
120OWN BUILTRTT9MTR47WSKITTEDRTT 9MTR 47WS G+3 KITTED
121OWN BUILTRTT9MTR47WSKITTEDRTT 9MTR 47WS G+4 KITTED
122OWN BUILTRTT9MTR50WSKITTEDRTT 9MTR 50WS G+2 KITTED
123OWN BUILTRTT9MTR50WSKITTEDRTT 9MTR 50WS G+3 KITTED
124OWN BUILTRTT9MTR50WSKITTEDRTT 9MTR 50WS G+4 KITTED
125OWN BUILTRTT6MTR39WSNON KITTEDRTT 6MTR 39WS G+2 NON KITTED
126OWN BUILTRTT6MTR39WSNON KITTEDRTT 6MTR 39WS G+3 NON KITTED
127OWN BUILTRTT6MTR39WSNON KITTEDRTT 6MTR 39WS G+4 NON KITTED
128OWN BUILTRTT6MTR47WSNON KITTEDRTT 6MTR 47WS G+2 NON KITTED
129OWN BUILTRTT6MTR47WSNON KITTEDRTT 6MTR 47WS G+3 NON KITTED
130OWN BUILTRTT6MTR47WSNON KITTEDRTT 6MTR 47WS G+4 NON KITTED
131OWN BUILTRTT6MTR50WSNON KITTEDRTT 6MTR 50WS G+2 NON KITTED
132OWN BUILTRTT6MTR50WSNON KITTEDRTT 6MTR 50WS G+3 NON KITTED
133OWN BUILTRTT6MTR50WSNON KITTEDRTT 6MTR 50WS G+4 NON KITTED
134OWN BUILTRTT9MTR39WSNON KITTEDRTT 9MTR 39WS G+2 NON KITTED
135OWN BUILTRTT9MTR39WSNON KITTEDRTT 9MTR 39WS G+3 NON KITTED
136OWN BUILTRTT9MTR39WSNON KITTEDRTT 9MTR 39WS G+4 NON KITTED
137OWN BUILTRTT9MTR47WSNON KITTEDRTT 9MTR 47WS G+2 NON KITTED
138OWN BUILTRTT9MTR47WSNON KITTEDRTT 9MTR 47WS G+3 NON KITTED
139OWN BUILTRTT9MTR47WSNON KITTEDRTT 9MTR 47WS G+4 NON KITTED
140OWN BUILTRTT9MTR50WSNON KITTEDRTT 9MTR 50WS G+2 NON KITTED
141OWN BUILTRTT9MTR50WSNON KITTEDRTT 9MTR 50WS G+3 NON KITTED
142OWN BUILTRTT9MTR50WSNON KITTEDRTT 9MTR 50WS G+4 NON KITTED
143OWN BUILTRTP3MTR39 47 50WSKITTEDRTP 3MTR 39 47 50WS G+2 KITTED
144OWN BUILTRTP3MTR39 47 50WSKITTEDRTP 3MTR 39 47 50WS G+3 KITTED
145OWN BUILTRTP3MTR39 47 50WSKITTEDRTP 3MTR 39 47 50WS G+4 KITTED
146OWN BUILTRTP6MTR39 47 50WSKITTEDRTP 6MTR 39 47 50WS G+2 KITTED
147OWN BUILTRTP6MTR39 47 50WSKITTEDRTP 6MTR 39 47 50WS G+3 KITTED
148OWN BUILTRTP6MTR39 47 50WSKITTEDRTP 6MTR 39 47 50WS G+4 KITTED
149OWN BUILTRTP9MTR39 47 50WSKITTEDRTP 9MTR 39 47 50WS G+2 KITTED
50OWN BUILTRTP9MTR39 47 50WSKITTEDRTP 9MTR 39 47 50WS G+3 KITTED
151OWN BUILTRTP9MTR39 47 50WSKITTEDRTP 9MTR 39 47 50WS G+4 KITTED
152OWN BUILTRTP3MTR39 47 50WSNON KITTEDRTP 3MTR 39 47 50WS G+2 NON KITTED
153OWN BUILTRTP3MTR39 47 50WSNON KITTEDRTP 3MTR 39 47 50WS G+3 NON KITTED
154OWN BUILTRTP3MTR39 47 50WSNON KITTEDRTP 3MTR 39 47 50WS G+4 NON KITTED
155OWN BUILTRTP6MTR39 47 50WSNON KITTEDRTP 6MTR 39 47 50WS G+2 NON KITTED
156OWN BUILTRTP6MTR39 47 50WSNON KITTEDRTP 6MTR 39 47 50WS G+3 NON KITTED
157OWN BUILTRTP6MTR39 47 50WSNON KITTEDRTP 6MTR 39 47 50WS G+4 NON KITTED
158OWN BUILTRTP9MTR39 47 50WSNON KITTEDRTP 9MTR 39 47 50WS G+2 NON KITTED
159OWN BUILTRTP9MTR39 47 50WSNON KITTEDRTP 9MTR 39 47 50WS G+3 NON KITTED
160OWN BUILTRTP9MTR39 47 50WSNON KITTEDRTP 9MTR 39 47 50WS G+4 NON KITTED
161OWN BUILTRTP-H FRAM3MTR39 47 50WSKITTEDRTP H FRAME 3MTR 39 47 50WS UPTO G+4 KITTED
162OWN BUILTRTP-H FRAM6MTR39 47 50WSKITTEDRTP H FRAME 6MTR 39 47 50WS UPTO G+4 KITTED
163OWN BUILTRTP-H FRAM9MTR39 47 50WSKITTEDRTP H FRAME 9MTR 39 47 50WS UPTO G+4 KITTED
164OWN BUILTRTP-H FRAM3MTR39 47 50WSNON KITTEDRTP H FRAME 3MTR 39 47 50WS UPTO G+4 NON KITTED
165OWN BUILTRTP-H FRAM6MTR39 47 50WSNON KITTEDRTP H FRAME 6MTR 39 47 50WS UPTO G+4 NON KITTED
166OWN BUILTRTP-H FRAM9MTR39 47 50WSNON KITTEDRTP H FRAME 9MTR 39 47 50WS UPTO G+4 NON KITTED
Projects Pic
TECHNICAL WORK PACKAGE CIVIL AND ERECTION (GBT) WORK
Civil WorkSite Preparation and RestorationSite Clearance pre and post foundation work and removal of obstructions, Plot levelling, disposing of the debris / muck / other material to suitable place as directed by EIC Site restoration on as it was basis.
Raft Work (Foundation of Tower)Excavation for spread footing in all type of Soil, Soft RockEarthwork in excavation for foundation for structures in all types of soil /soft rock, including dressing of bottom and sides of foundations, stacking excavated selected earth for backfilling, clear from the edges of the foundations, including dewatering, pumping and bailing out water etc as specified in drawing specification. item include shoring and strutting etc .if required.
 Steel ReinforcementSteel Reinforcement as per IS 1786 for raft foundation Providing, fabricating and fixing Reinforcement steel with binding wires including all manpower, tools, tackles, laps, chairs etc.. Complete as per the site requirement, drawing and direction of EIC
 PCC (Plain Cement Concrete) [ M 10]Providing and Laying 75 mm (or as specified in drawing) thick PCC of Grade M10 for blinding work below raft including mixing, curing, watering, ramming / Vibrating , Shuttering all complete as per the direction of EIC. It includes necessary dewatering, pumping and bailing out water.
 Form Work/ShutteringSupply, fabrication and fixing the shuttering – Ply / MS in Line, Level and Plumb as per the specification / drawing.
 Concrete Work (RCC M-20) for Raft + ColumnSupply and laying of M-20 nominal mix RCC for Raft, Column, Beam & SLab as specified in Drawing and specification as per direction of EIC
 Backfilling Filling with excavated normal soilFilling of exavated portion after completion of foundation upto the finish level as per drawing with Approved excavated/borrowed soil with compaction to achieve 97% FDD.
 Supply & installation of 100 dia PVC pipe in DG slab for cable entry, as per drawing & instruction of EIC. 
Foundation Bolts & Template workFixing and Alignment of stubs/foundation bolts/CIPTransportation from WH to site (or Site to site) including loading – unloading and Fixing & Alighment of lattice tower stubs / foundation bolts/ CIP and positioning as per the drawing
Tower ErectionErection of Tower with Accessories ladder, platform, LA, fencing, EPFErection of the towers and accessories which includes ladder, platform, railing, antenna mount pole, lightening arrestor, Fencing, EPF.etc as per drawing. Damage and Tack Welding of Foundation/intermediate bolts after Tower Erection etc. Scope of Work Includes: BoQ segregation, Collection, Inspection, Minor Repair work, Erection at site. cannibalizing returning of surplus material and teamplate to warehouse Note:- Lightening arrestor will be part of Tower scope.
 Pole Mount Installation (RF single/dual) – set of 3 Nos. (wt.=66.67×3=60kg) 
 Pole Mount Installation (MW/Single) (wt-50kg)Installation of 3 dual pole mountsand 2 MW pole mount
 Transportation of Tower with Accessories & Pole Mount upto 100 kmTransportation of Tower Systems (Including , unloading handling at site)
Boundary/ Support WallBoundary/ Support Wall with brick work along with Plot Demarcation Blocks (250 X 250 X 1000)Plot boundary demarcation by Random rubble/brick masnory Providing and constructing demarcation blocks & brick masonry Support wall around raft/plot area, 300mm below FGL and 60mm above FGL with 230mmthk, in CM 1:6 mortar, with 16mm plaster 1:4 on exposed surfaces, using approved quality locally available bricks as per the approved drawing & specifications. Brick masonary should be plastered with 1:4 mortar on the exposed faces. This is to prevent soil erosion due to storm water or due to raised height of Tie beam/DG Platform. It includes watering prior to laying, soil compaction, raking out joints, curing after construction etc., complete in all respect as per drawing, as directed by Engineer -in-charge. Demarcation blocks: are RCC M-20 blocks (250x250x1000) with 4 vertical 10dia bars tied with 8dia rings at 225mm c/c.
Projects Pic
General Guidelines For Techncial & Constructional Work
Sr.No.Activity
1Pre- Planning, scheduling, co-ordination & Site preparation activities
1.1Plan necessary resources (Documents, Man, Machinery and Material), acquire, prepare & provide necessary information/data, fill-in the forms, and get the necessary approvals and sanctions from the concerned authorities, internal as well as external authorities as necessary for chain of actions and process.
1.2Prepare and submit a reports about the Liquidation Plans, progress of work and details about work completed. The reports shall be in specified formats, periodical and/or as and when required. Generally, weekly / monthly .
1.3All out efforts are to be made to optimise the Cost and time, quality and safty of the work adhering to all working standards, rules and regulations, stipulated or implied at the time of work and as revsied and updated from time to time.
1.4Regular and necessary follow-ups, internally with various teams for compliance of necessary documentation and approvals as well as externally. All the progress/details are share the details related to status of the work with the IBSL representative.
1.5All efforts are to be made to complete the scope within basic scope of work and withoiut any extra work requirements. Any special case requiring extra work for getting the connection shall be brought to the notice of Owner/his representative as per existing process, get it approved by providing supporting information/details.
1.6As time, quality & safety are prime essence of the Contract, a perfect co-ordination shall be done so that work shall be started at site within 48 hours of intimation by EIC.
2Laisoning & Local cordination with authorities
2.1Liaison with local authorities, building owner,residents, commuters neighbours etc. has to be co-ordial and smooth, the differences , if any, has to resolved independely without any direct or indirect involment of Owner and at his own responsibility.
2.2Liaison & resolve the local issues, if any, at site e.g. police, neighbours, authorities etc.during execution of onsite work.
3Safty precautions for men & material
3.1Ensure Safety of the all personnel involved in activity and personnel nearby the site from any mishaps as per the approved Safety Plan (R4G-70-CSP-PR-CH-001-00)
3.2A due care shall be taken for the safety/ barricading at site and arrangements like signage boards, warning tapes etc. shall be made to ensure safety & to have minimum inconvenience to local public. Best working practices are to be adhered and made to ensure safety & to have minimum inconvenience to local public. Best working practices are to be adhered and maintained.
4Following of Correct drawings & guidelines and timely completion of work :
4.1Vendor has to follow the Drawings and technical guidelines issued by Owner or his representaive, deviations , if any, are to be pointed out and got approved/cleared from proper authorities. Any specific requirements stated by external authorities are to be brought to the notice of owner and got resolved.
4.2Receive and Transport FIM; if any as per Scope/WO from designated Warehouse to the Site location and protect the material from theft/damage till completion of Work and Handing over of the site.
4.3The Vendor has to collect the FIM, ( whenever so informed), utilise it extensively , reconcile and Return and account the balance for further necessary action.
4.4In case of transportation/ loading unloading and storing at site, the safty and security shall be fully in the scope of Vendor.Pilfrages and damages are to be at cost of Vendor without affecting the timelines of work execution and quality of installations.
4.5Arrange for adequate skilled manpower with tools & tackles for carrying out work.
4.6If the work has to be executed at night, necessary arrangements for illuminating the site to be done by vendor. Prior intimation to the EIC is mandatory for undertaking jobs at night-time; however this does not absolve the contractor from any responsibility from carrying out hassle free execution.
5WIP & Progress Qaulity checks & corrections
5.1To attend actual progress review meetings and all other meetings as required by the EIC and submit all data / information required by EIC for progress and quality of the materials / workmanship.
5.2To prepare and submit daily progress reports to EIC in the prescribed format giving all the details based on the agreed delivery schedule. The Critical areas of concern should be clearly brought out in order to seek timely intervention for resolution.
5.3The Safeguarding and restoration of utilities, boundary wall, foot path, structure etc. in acceptable condition post completion which may obstruct during the work.
6Re-furbishment, disposal & return of excess, removed material, handing over activities.
6.1To remove and dispose of the packing material/ waste materials from site and leave the site in absolute clean manner
6.2Submit site Acceptance Test report along with approved checklist and the original documents
6.3In some sites, if permanent electricity power in first go is not available, alternate power possibility may be worked out to complete the activities.
6.4Contractor to Comply with Quality and Safety Audit Findings and ensure the Punch Points liquidation within agreed timeline.
6.5The Vendor has to maintain high professional standards while working, co-ordinating and dealing with others , adhere to various rules and regulations stated or implied, in force during any period of time with due care and efforts.

 

Projects Pic